Magnetic Microspheres
Latex Microspheres
Dyed Microspheres
Fluorescent Microspheres
Flow Cytometry Microspheres
Standard Microspheres
Size Exclusion Resins
Focurose 30PG
Focurose 200PG
Focurose 75PG
Focurose 6FF
Focurose 4FF
Ion Exchange Resins
Affinity Resins
Hydrophobic Interaction Resins
Multimodal Resins
Pre-activated Resins
Homogeneous Luminescent Immunoassay
Instruments and Reagent
Focurose 6FF
sample

Focurose 6FF is designed for component separation and moderate purification of biological macromolecules by removing small molecular impurities. It is suitable for applications such as virus particles, large protein molecules, supercoiled DNA, polysaccharides, and macromolecular complexes.

 

IMG_5879(1).jpg


Features

  • High (physicochemical) stability, high flow rate (component separation), and high recovery rate (up to 95%)

  • Gentle elution conditions to preserve the biological activity and functionality of biological macromolecules

  • Easy to scale up

  • Easy to maintain


Focurose 6FF Performance Parameters 

 

Resin

Highly cross-linked 6% agarose

Particle size range  

45-165µm

Average particle size (D50)

90±5µm

Separation range (globular proteins)

10-4000 kDa

pH stability

2-12 (long-term) 2-14 (short-term)

Chemical stability

2M sodium hydroxide, 70% ethanol, 30% isopropanol, 30% acetonitrile, 1% SDS, 6M guanidine hydrochloride, 8M urea

Linear flow velocity (0.3 MPa)

≥300 cm/h

Maximum pressure

0.3 MPa

Storage solution

20% ethanol

Storage conditions

4℃-30℃

 

Frequently Asked Questions and Solutions


Issue

Possible Causes

Solutions

Rapid increase in chromatographic peak

Overly tight packing of the resin

Repack the column

Slow or tailing chromatographic peak

Loose packing of the resin

Repack the column

Cracks or dryness in the column bed

Leakage or introduction of large air bubbles

Check for leaks or bubbles in the tubing and repack the column if necessary

Poor separation efficiency

1. Inappropriate choice of matrix

Verify if the selected matrix is suitable

2. Poor column performance

Evaluate the column efficiency

3. Oversampling

Optimize the optimal sampling volume

4. Excessive flow rate

Optimize the optimal flow rate

Slow liquid flow

1. Protein or lipid aggregation

Clean the matrix or filter membrane promptly

2. Protein precipitation in the matrix

Adjust the composition of equilibration and elution buffers to maintain the stability of the target substance and the binding efficiency of the matrix

3. Microbial growth in the separation column

Reagents used must be filtered and degassed; samples must be centrifuged or filtered before loading onto the column



Order information


Product

Specification

Item number

Focurose 6FF

25mL

HN060307025M

Focurose 6FF

100mL

HN060307100M

Focurose 6FF

500mL

HN060307500M

Focurose 6FF

1L

HN060307001L

Focurose 6FF

5L

HN060307005L

Focurose 6FF

20L

HN060307020L


Search